(813) 803-6535 Book a Repair
Model library · U-Line ice machine

U-Line CLR2060 repair

Early Echelon 2000 clear ice maker, Echelon 2000. Service for this model across Tampa Bay.

U-Line ice maker repair in Tampa Bay
Model
CLR2060
Type
Early Echelon 2000 clear ice maker
Series
Echelon 2000
Years
Echelon 2000 (first generation)
Brand
U-Line

About the CLR2060

Beneath the counter of a home bar or kitchen sits the CLR2060, a clear ice maker from the earliest Echelon 2000 generation. It freezes water in layers on a chilled plate, which relies on clean water, a working drain and good sensing.

Control board 68003, with a diagnostic LED, guides a CLR2060 visit. If the overflow-protection LED flashes on a unit with the P-60 pump, we check the pump for scale. A particular LED pattern points to a thermistor out of range. Slow harvests that leave cubes on the grid, low flow at the inlet valve and a dusty condenser grille complete our list. The price is written first.

What we check on a CLR2060 visit

  • Overflow-protection flash, for the P-60 pump
  • Diagnostic LED pattern, for the thermistor
  • Inlet flow, harvest speed and condenser grille

Key features

  • Clear ice maker from the first Echelon 2000 generation
  • Control board 68003 carries a diagnostic LED
  • Overflow protection flashes when the P-60 pump is fitted
  • Placed beneath the counter

The model number is on the serial label: inside the cabinet near the top, on the side wall or behind the front grille. We are an independent repair company, not affiliated with U-Line Corporation.

FAQ

CLR2060 questions

What does the overflow flash on my CLR2060 mean?

On units with the P-60 pump, it is the overflow protection, and a pump clogged with scale is a likely cause. We clean the pump and check the drain.

Why is the ice from my CLR2060 thin or cloudy?

A restricted water inlet valve is a common reason. We test flow into the unit and clear or replace the valve.

Call Book a Repair
Call (813) 803-6535 Book a Repair