U-Line BI95 repair
Legacy built-in crescent ice maker. Service for this model across Tampa Bay.

- Model
- BI95
- Type
- Legacy built-in crescent ice maker
- Years
- Legacy model
- Brand
- U-Line
About the BI95
The BI95 follows the older numbering, with 95 for the cabinet and BI for built-in. Crescent ice comes from its harvest cycle, and a lever in the bin ends the run rather than an electronic sensor, so its behavior is simple to interpret.
Moving parts decide how a BI95 ages, so we begin with the harvest motor that turns every cycle, then the inlet valve that fills the mold and may no longer close cleanly. The bin lever is last, since a lever that sticks halts production. We state the price in writing before working.
What we check on a BI95 visit
- Harvest motor, when cycles slow or stop
- Inlet valve shutoff, when the mold overfills
- Bin lever movement, when ice production halts
Key features
- Built-in crescent ice maker under the legacy numbering
- The 95 cabinet code plus the BI prefix
- Crescent ice made in a harvest cycle
- Bin-full shutoff by a mechanical lever
The model number is on the serial label: inside the cabinet near the top, on the side wall or behind the front grille. We are an independent repair company, not affiliated with U-Line Corporation.
U-Line ice machine codes
Codes listed for U-Line ice machines. Which ones a unit can show depends on its control generation, so we confirm by the full model number.
Other U-Line ice machine models
Modular 3000 Series3018CLR18-inch Modular clear ice machine
Modular 3000 Series3045CLRWide Modular clear ice machine
ADA SeriesACP11515-inch ADA clear ice machine
ADA SeriesACR01414-inch ADA crescent ice maker
ADA SeriesACR01515-inch ADA crescent ice maker
ADA SeriesACR11515-inch ADA crescent ice maker
Ice MachineADA15IMOlder 15-inch ADA ice maker
ADA SeriesANB11515-inch ADA nugget ice machineBI95 questions
How does the BI95 know the bin is full?
A mechanical lever rides on the ice in the bin and trips a switch. If the lever sticks, the machine may stop too soon or run too long, so we check its travel.
Why does my BI95 leak water into the bin?
An inlet valve that no longer shuts cleanly lets water drip into the mold between cycles. We test the valve and replace it if it seeps.