(813) 803-6535 Book a Repair
U-Line ice machine error code

U-Line Ice Maker Bin T Short: Bin Thermistor Shorted Circuit

Bin T Short tells you the bin thermistor circuit in your U-Line ice maker is bridged, and the storage bin temperature is lost. Damaged wiring, moisture or a failed sensor can cause it.

Needs attention soonChecked November 2026

What does U-Line ice machine code Bin T Short mean?

Bin T Short is the U-Line ice maker message for a bridged bin thermistor circuit, which leaves the board with no dependable storage-bin temperature. A shorted circuit sends a signal that does not match a real reading. A pinched or damaged wire, a sensor that has stopped working, or moisture on the connector are the causes linked to it. The ice bin is cold and often damp, so a wet connector is a realistic thing to check, though the message does not confirm it.

Bin T Short at a glance

Code
Bin T Short
Appliance
U-Line ice machine
Applies to
U-Line ice makers that sense bin temperature
Type
Needs attention soon
Can you clear it yourself?
Sometimes, after the safe checks below
Most likely cause
A pinched or damaged wire on the bin thermistor

What you may notice with Bin T Short

  • The display shows Bin T Short
  • There is meltwater in the bin or near its edges
  • Ice looks wet or fused together
  • The unit is making less ice than before

How the ice machine detects Bin T Short

In your ice maker the finished ice drops into a bin, and a thermistor in that area reports its temperature to the control. Resistance in the sensor rises and falls as the bin warms and cools, and the board turns that into a reading it uses alongside other sensors.

A sound circuit gives a resistance that fits a believable bin temperature. If the circuit is bridged, whether by a pinched wire, a failed sensor or water on the connector, the resistance drops far outside that range. The control cannot make a real temperature from it and reports Bin T Short. Since the bin is meant to keep ice cold and solid, losing this reading limits how well the unit can manage what it stores.

Likely causes of Bin T Short

  • A pinched or damaged wire on the bin thermistor
  • A bin thermistor sensor that has failed
  • Moisture on the bin sensor connector

Can you keep using the ice machine with Bin T Short?

You may run the ice maker for a short while, but inspect the ice and the bin often. If water is pooling, the ice looks soft or you smell something hot, switch off the breaker and wait for service. A wet electrical connection is the reason for extra care here.

What you can safely check

  1. Switch the ice maker off, disconnect it from power at the breaker, and, where the shutoff is close, turn the water off there.
  2. Let it sit for about a minute and power it up again.
  3. Look at the bin for meltwater or ice stuck against the walls, and leave the sensor area alone.
  4. Watch whether Bin T Short returns.
  5. If it does, call us and tell us if the bin was wet.

What our technician does for Bin T Short

  • Check the bin thermistor wire for pinches or insulation damage
  • Inspect the connector for water or corrosion
  • Test the bin sensor and replace it if the reading is wrong

How to keep Bin T Short from coming back

  • Keep the bin drain clear so meltwater does not collect
  • Close the door fully each time so warm humid air stays out
  • Wipe up spills around the bin edge instead of letting them run back
  • In Florida's humid months, check the door gasket for a clean seal

Technical reference

Code
Bin T Short
Appliance
U-Line ice machine
Control family
U-Line ice makers that sense bin temperature
Checked
November 2026

Code meanings come from the maker’s documentation and our own repair work; we do not reprint the maker’s document. Confirm the full model number before acting on a code. We are an independent repair company, not affiliated with U-Line Corporation.

FAQ

Bin T Short questions

Why would a bin sensor get wet?

The bin holds ice, and ice melts into water that can run toward connectors. If that water reaches the contacts, it can bridge them and make the circuit look shorted.

Does the code mean the bin is too warm?

No. It means the sensor signal is not trustworthy, which is different from a warm reading. The bin may be perfectly cold, but the control cannot confirm it.

Can I clear it by emptying the bin?

Emptying the bin can help dry things out, but if the wire or the sensor is the problem the message returns. A restart after drying is a fair thing to try before calling.

Is Bin T Short caused by a bad ice scoop or ice stuck in the bin?

Ice or a scoop will not bridge a sensor circuit by themselves. Water and damaged wiring can. If ice has frozen around the sensor area, mention it so the technician checks the wire and connector.

What happens if I keep running it?

The unit may keep making limited ice or stop altogether, and the message will usually remain. Meanwhile, moisture on a connector can cause corrosion, so having it checked sooner is sensible.

Need help with Bin T Short?

A technician finds the cause at your bar or lanai and puts the price in writing before any part comes out.

Call Book a Repair